Accident Analysis of Lightning Disasters Induced by Communication Base Station Construction
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 圖/表
  • |
  • 訪問統計
  • |
  • 參考文獻
  • |
  • 相似文獻
  • |
  • 引證文獻
  • |
  • 資源附件
  • |
  • 文章評論
    摘要:

    針對大足縣城南中學附近建設移動通信基站后頻遭雷擊的狀況,結合2006—2009年重慶地區ADTD閃電定位系統監測資料,重點分析該校頻遭雷擊事故原因。結果表明:移動通信基站建設(增加了遭受直擊雷和雷擊電磁脈沖影響概率)是城南中學頻遭雷擊的誘因;該校未安裝防雷裝置,且部分教學樓處于鐵塔保護范圍外,而位于雷擊鐵塔的散擊區內,是頻遭雷擊的直接原因。

    Abstract:

    The causes of frequently occurred lightning accidents in the Chengnan Middle School of Dazu County, Chongqing after a mobile communication base station was constructed are analyzed by means of the monitoring data of the ADTD lightning location system in Chongqing from 2006 to 2009 The results show that the construction of the mobile communication iron tower increased the lightning strike probability of the Chengnan Middle School and the influence of lightning electromagnetic impulses, which is the major cause of the frequently occurred lightning accidents. The teaching building frequently stroke is out of the protective range of the iron tower, located in the lightning scattered strike zone of the iron tower, and does not have lightning protection devices.