    摘要:

    針對ADTD雷電定位監測系統在運行過程中出現的異常情況,從雷電定位儀器異常、網絡通信模塊異常、中心站接收機異常、中心站軟件異常幾個方面來分析系統故障的成因。歸納指明了在出現異常情況時,系統維護人員解決故障的相關方法和措施。排查分析系統異常的主要依據是ADTD雷電定位監測系統的數據處理流程和基本運行原理。

    Abstract:

    In view of the abnormal situation in the running process of the ADTD Lightning Location Monitoring System, an analysis is made of the causes of system failures caused by the abnormalities in the lightning location equipment, network communication module, central station receivers, and central station software. The relevant methods and measures used by the maintenance staff in troubleshooting are summarized. The abnormality analysis of the system is mainly based on the dataprocessing procedures and basic operating principles.