    摘要:

    針對近年來全國許多臺站安裝使用CAW9600B(S)型自動氣象站的實際情況,討論了CAWS600B(S)型自動氣象站DY01電源系統原理,通過對整流濾波電路、中央控制電路、充電及穩壓輸出電路的原理分析,介紹了交流輸入電路、中央控制電路、充電及直流輸出電路可能出現的故障及檢測、維修方法,為自動氣象站的維護和維修提供一些方法和經驗。

    Abstract:

    The principles of the DY01 power system used in the automatic weather station CAWS600B(S) are introduced, and the rectifier and filter circuit, central control circuit, charging and stabilizing circuit are analyzed. The typical failures which may happen in various parts of the circuits are discussed and the corresponding detection and maintenance methods are presented, which are helpful to the maintenance of automatic weather stations across China.